CHAPTER 3 SYSTEM DATA PROGRAMMING
– 135 –
NWA-008855-001 Rev.1.0
avch3001.fm
NOTE: When setting the Digital Announcement Trunk (DAT) as the destination of Call Forwarding-PS
Out of Cell, set the data for “Announcement-PS No Answer/Announcement-PS Out of Cell”.
Page 130
DESCRIPTION DATA
Specify that the RBT is not sent when the
called PS is out of cell or the power is off.
NOTE: CM08>503 is effective only for Sta-
tion-to-Station call.
(1)
(2)
503
0: Not sent
Specify the timer for a distinction whether the
called PS is out of cell/power is off, or not.
(1)
(2)
Y=0
85
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 8-12 sec-
onds.
When setting the destination of Call Forward-
ing-PS Out of Cell from MAT/CAT, set the
destination to the Virtual station number as-
signed by CM14.
(1)
(2)
Y=06
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
Destination No.:
X-XXXXXXXX: Station No.
E000: Attendant Console
YY...Y: Outgoing Trunk Access Code (1-4
digits) + + Called No. (Maxi-
mum 26 digits)
A
CM08
CM41
CME6
,
END