Loading...
Station Hunting - Not Available
Page 42 ND-91638-007(E)
Issue 6
9. Operating Conditions in Station Hunting - Terminal
When a pilot station number is dialed, and that Station A is out of cell or power off, a call will be terminated
to Station B in a hunt group a few seconds later. (If B is busy or set Call Forwarding, a call will be terminated
to Station C.)
When a station other than the pilot station is dialed (or the pilot station forwards a call to that station), and
when that station is out of cell or its power is off, the call is not forwarded to other stations (The calling
party will continue to receive ringback tone).
10. Operating Conditions in Station Hunting - Circular
When a call is terminated to any stations in a hunt group, and the station, to which that call is terminated, is
out of cell or its power is off, that call will be forwarded to the next station in a few seconds.
If the forwarded station is out of cell or its power is off, a call will be forwarded to the next station in a hunt
group in a few seconds.
A
(CM18 Y=1>1)
B
(CM18 Y=1>0)
D
(CM18 Y=1>0)
(CM18 Y=1>0)
E
(CM18 Y =1>0)
F
(CM18 Y =1>0)
C
Station Hunting - Terminal
A
(CM18 Y=1>1)
B
(CM18 Y=1>1)
(CM18 Y=1>1)
C
D
(CM18 Y=1>1)
E
(CM18 Y=1>0)
F
(CM18 Y=1>1)
Station Hunting - Circular