5-2 Troubleshooting and Options for the Docking Station II
Table Section 5-1 Docking Station II Problems and Solutions
Problem Corrective Action
Parallel device does not work. 1. Check that the parallel device is powered on.
2. Check that the system is configured for a parallel device.
3. Check parallel device cable connection.
CRT does not show data. 1. Make sure CRT is turned on.
2. Check CRT cable connection.
Keyboard does not work. 1. Check keyboard connection.
2. Check LED interface cable connection.
Mouse does not work. 1. Check mouse connection.
2. Make sure mouse driver is installed.
3. Check interface cable connection.
LED lamp does not work, 1. Check LED interface cable.
2. Replace LED interface cable.
3. Replace the hard disk drive cable.
4. Replace the hard disk drive.
Battery is not charged. 1. Make sure the battery is installed.
2. Make sure the Versa is connected securely.
3. Check that the main power switch is set to on.
4. Check that the internal connectors are connected securely.
ISA board does not work. 1. Check the jumper setting.
2. Install software and device drivers if not installed.
3. Make sure each ISA option board is connected securely.