# Parameter Explanation Unit/Range Default
11.
Minimum Step
size
Define the minimum percentage for
opening/closing the vent from the
current position to the calculated. If
calculated position percentage is below
this percentage, then the vent will not
increase/decrease its position.
0 - 100% 10%
12.
Maximum
wind when
rain
The position of the vent during
emergency event Rain
0 - 100% 0
13.
Maximum lee
during rain
14.
Maximum
wind during
storm
The position of the vent during
emergency event Storm
0 - 100% 0
15.
Maximum lee
when storm
16.
Vent Position
During
External
Contact
In case that working with external
contact, when event occurs, the vent
position is according to the definitions
0 - 100% 0
17.
Min. Wind for
vent influence
Above this speed, vent begins to close
by the levels set in the following two
parameters.
Km/hour
(099)
18
18.
Maximum
Vent lee (Min.
Wind)
Maximum vent opening on the lee/wind
side when wind speed is above the Min.
Wind for Vent Influence.
% (0 100) 100
19.
Maximum
Vent wind
(Min. Wind)
% (0 100) 80
20.
Maximum
Wind for vent
influence
When the wind speed reaches this level,
vents close to the levels set in the
following two parameters.
Km/hour
(1100)
54