EDH0162En1040 06/99 3.176
MM4005 XN Read number of acquisitions
Usage IMM PGM MIP
Syntax XN
Parameters
None.
Description This command reads the current number of trace acquisitions. During a
trace mode initiated by the TM command, the number of stored samples
can be read to monitor the progress of the acquisition process.
Returns XNnn
nn
Nnumber of acquired samples.
Errors S Communication time-out.
Rel. Commands None.
Example
SP 0.005 | Set trace sample period to 5 ms.
2TM1000 | Enable trace mode for axis #2 and acquire 1000 samples.
2PR0.2 |
Start a relative motion on axis #2 and the acquisition process.
XN | Read the number of samples acquired.
XN157 | Controller reports 157 trace samples acquired.
XN | Read the number of samples acquired.
XN342
| Controller reports 342 trace samples acquired.
2WS, XN | Wait for stop and read the number of samples acquired.
XN1000
| Controller reports 1000 trace samples acquired.