Appendix C Technical
Specifications
User Manual for EL170/970/470 IP Satellite Modulator/
Demodulator/Modem
version 4.2
189
SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS
Internal Reference frequency
High Stability (optional)
Stability ±5x10 over 0°C to 70°C;
Ageing: ± 15 ppb/day ± 300 ppb/year.
Very High Stability (optional)
Stability: ±2x10 over 0°C to 65°C;
Ageing: ± 0.5 ppb/day ± 500 ppb/10 year.
Generic
10 MHz reference input / output (optional)
Connector BNC (F) 50 ohms;
Input level -3dbm up to 7dBm;
Output level +7dBm.
LNB reference frequency output (optional, only available with L-band)
Frequency 10 MHz;
Stability +/- 5x10-8 over 0°C to 65°C;
Warm up time 5 min (+/-100ppb);
Ageing
- +/- 15 ppb/day;
- +/- 300 ppb/year.
Monitor and control interfaces
Web based GUI;
Diagnostics report, alarm log;
RMCP over TCP-IP/UDP and RS232/RS485;
SNMP v2c.
Alarm interface
Electrical dual contact closure alarm contacts;
Connector 9-pin sub-D (F);
Logical interface and general device alarm.
LNB reference frequency output (optional, only available with L-band)
Frequency 10 MHz;
Stability +/- 5x10-8 over 0°C to 65°C;
Warm up time 5 min (+/-100ppb);
- ageing +/- 15 ppb/day;
- +/- 300 ppb/year.