Chapter 12 SNMP Configuration 139
BCM50a Integrated Router Configuration — Advanced
SNMP Traps
The BCM50a Integrated Router will sends traps to the SNMP manager when any
one of the following events occurs:
Table 28 SNMP Traps
Trap # Trap Name Description
0 coldStart (defined in
RFC-1215)
A trap is sent after booting (power on).
1 warmStart (defined in
RFC-1215)
A trap is sent after booting (software reboot).
4 authenticationFailure (defined
in RFC-1215)
A trap is sent to the manager when receiving
any SNMP get or set requirements with the
wrong community (password).
6 whyReboot (defined in MIB) A trap is sent with the reason of restart
before rebooting when the system is going to
restart (warm start).
6a For intentional reboot: A trap is sent with the message "System
reboot by user!" if reboot is done
intentionally, (for example, download new
files, CI command sys reboot, and others).
6b For fatal error: A trap is sent with the message of the fatal
code if the system reboots because of fatal
errors.