AMG-1 and AMG-E Audio Message Generator
 9RLFH $ODUP 6
\
VWHPV
AFC-600 Operations PN 51033:A 3/8/99 59
$0* DQG $0*( 7RQH0HVVD
J
H 6HOHFWLRQV $0* 6: 2Q
Table 23 lists
the audio tone and message selections available when SW2 DIP switch 2 (Tone/
Message switch) is On.
7DEOH  6HWWLQ
J
$0* 7RQHV DQG 0HVVD
J
HV $0* 6: 2Q
Notes:
1. You can manually select MPS-6 Notification Appliance Circuit 1 (NAC 1) with an
ACM-16AT to produce a desired tone or it can be activated through
Control-By-Event by a Non-Alarm input.
2. If selecting a VROM or VRAM that is not installed, a trouble will be generated at
the AMG-1 and the AMG-1 generates the interrupted 1 kHz default tone.
3. Boston Code (order VROM-109, which must be installed in VROM-B position)
900 Hz alert tone pulsed to produce one round of code 4 at approximately one
second intervals, followed by female voice message:
´$WWHQWLRQ
S
OHDVH 7KH VL
J
QDO WRQH
\
RX KDYH
M
XVW KHDUG LQGLFDWHV D UH
S
RUWRIDQHPHU
J
HQF
\
LQ WKLV EXLOGLQ
J
,I
\
RXU IORRU HYDFXDWLRQ VL
J
QDO VRXQGV DIWHU WKLV PHVVD
J
H ZDON WR WKH QHDUHVW VWDLUZD
\
DQG OHDYH WKH IORRU
:KLOH WKH UH
S
RUW LV EHLQ
J
YHULILHG RFFX
S
DQWV RQ RWKHU IORRUV VKRXOG DZDLW IXUWKHU LQVWUXFWLRQVµ
This message repeats. The evacuation signal is a slow-whoop tonean ascending
tone that starts at approximately 600 Hz and ends at approximately 1100 Hzwith
a duration of approximately 3.5 seconds and an interruption between tones of
approximately 0.5 second.
AMG-1 SW2 Rocker
Switches
System
Status
NAC 1 (B01)
Condition
Audio Tone or Message
S6 S7 S8
X X X No Alarm Off Standby
Off
Off
Off
Off
Off
Off
No Alarm
Alarm
On
Off
Horn
1000 Hz 1/2 sec on, 1/2 sec off for 5 min.
then slow whoop
Off
Off
Off
Off
Off
Off
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
Horn
20 ppm for 5 min., then 120 ppm
120 ppm (March Time)
Off
Off
Off
On
On
On
Off
Off
Off
No Alarm
Alarm
Alarm
On
Off
On
VROM-B
444, pause, VROM-A
Boston Code
Off
Off
Off
On
On
On
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
VROM-B
Fast whoop
3 fast whoops, pause, VROM-A
On
On
On
Off
Off
Off
Off
Off
Off
No Alarm
Alarm
Alarm
On
Off
On
Beep
Fast whoop
3 fast whoops, pause, VROM-A and
VROM-B
On
On
On
Off
Off
Off
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
Beep
3 slow whoops, pause, VROM-A
3 slow whoops, pause, VROM-A and
VROM-B
On
On
On
On
On
On
Off
Off
Off
No Alarm
Alarm
Alarm
On
Off
On
Wail
3 hi-low tones, pause, VROM-A
3 hi-low, pause, VROM-A and VROM-B
On
On
On
On
On
On
On
On
On
No Alarm
Alarm
Alarm
On
Off
On
Hi-low
20 ppm (Two-Stage)
3 Slow whoops, pause, VROM-A
X = Indicates that Switch or Control Point can be On or Off.
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Other manuals for Notifier AFC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier AFC-600 and is the answer not in the manual?

Notifier AFC-600 Specifications

General IconGeneral
BrandNotifier
ModelAFC-600
CategoryFire Alarms
LanguageEnglish

Related product manuals