DELAYED VIOLATION #2
(Fig. 100)
The ATOM cannot calculate Decompression times for Stop
Depths much greater than 60 FT (18 M) and offers no indication
of how much time spent underwater would result in the need for
a greater Stop Depth.
If the Decompression obligation requires a Ceiling Stop Depth
between 60 FT (18 M) and 70 FT (21 M), the TLBG will flash
and the graphic message DECO > STOP > 60F (18M) will scroll
at the top of the display.
When this occurs, you must make a controlled Ascent to just
deeper than, and stay as close as possible to, 60 FT (18 M)
without causing the TLBG to flash. When the Required Stop
Depth indicates 50 FT/ 15 M, etc., you can ascend to those
Stop Depths and continue decompressing.
DELAYED VIOLATION #3
(Fig. 101)
If you descend deeper than the Maximum Operating Depth of
330 FT (100 M), the UP Arrow will flash, and the Current Depth
and Max Depth displays will only indicate 3 dashes ( - - - )
signifying that you are Out of Range.
The graphic message TOO > DEEP will scroll at the top of the
display until Ascent is made above 330 FT (100 M).
Fig. 100 - DELAYED
VIOLATION #2 MAIN
Fig. 101 - DELAYED
VIOLATION #3 MAIN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oceanic ATOM 2.0 and is the answer not in the manual?

Oceanic ATOM 2.0 Specifications

General IconGeneral
BrandOceanic
ModelATOM 2.0
CategoryDiving Instrument
LanguageEnglish

Related product manuals