6. MAINTENANCE MENUS
Item1 Item2 Item3 Item4 Item5 Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password Scanner
Maintenance
Adjust Mech. Adjust ADF
Motor
ADF Keep
Current
10 ~ 1400 [mA]
200 [mA] 200 [mA]
Adjust CIS Adjust CIS simple
R continuous
G continuous
B continuous
All continuous
Only for engineering test
Sequentially light the designated RGB colors and check them during calibration
configuration duties.
Move the CIS to the standard position.
In the position moved to, sequentially light R, followed by G and B in the same
manner.
Light each color for approximately 3 seconds.
Display "Testing" during execution?
→
On the panel, display "CIS light testing" and "Cancel."
Check CIS 300dpi
600dpi
---Results Displayed---
CCD_SIG9_WID_H 0x000000
CCD_SIG2_WID_H 0x000000
Only for engineering test
Check CIS maintenance displays the exposure time at each resolution.
When resolution is set, scanner calibration is conducted at that
resolution and the
following results are displayed:
Red-1
Red-2 (No indication)
Green-1
Green-2 (No indication)
Blue -1
Blue-2 (No indication)
Lsync
Note : CIS exposure time varies with resolution.
Set CIS
Exposure
time
0 ~ 4294967295 Only for engineering test
Change LED exposure time settings, and then read the document using
PC Scan.
Reading implemented for the LED exposure time in the settings, without
conducting
calibration.
A warning is displayed when a value greater than the Lsync cycle has
been set.
Settings are shown below.
Red-1
Red-2 (No indication)
Green-1
Green-2 (No indication)
Blue -1
Blue-2 (No indication)
Lsync