Omron E5CSV User Manual

Omron E5CSV
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
xiv
Changing the SP ................................................................................ 3-7
3.6 Using ON/OFF Control....................................................................................... 3-8
ON/OFF Control ................................................................................. 3-8
3.7 Determining PID Constants (AT, ST, Manual Setup).......................................... 3-9
AT (Auto-tuning).................................................................................. 3-9
ST (Self-tuning) ................................................................................ 3-10
Manual Setup ................................................................................... 3-12
3.8 Alarm Outputs .................................................................................................. 3-14
Alarm Types...................................................................................... 3-14
Alarm Values..................................................................................... 3-14
3.9 Shifting Input Values......................................................................................... 3-16
Shifting Inputs................................................................................... 3-16
Section 4 Operations for Applications ......................................... 4-1
4.1 Moving to the Initial Setting Level....................................................................... 4-2
4.2 Assigning Outputs .............................................................................................. 4-3
Output Assignment............................................................................. 4-3
4.3 Alarm Functions ................................................................................................. 4-4
Alarm Hysteresis ................................................................................ 4-4
Standby Sequence ............................................................................. 4-4
Close in Alarm/Open in Alarm ......................................................... 4-5
Alarm Latch ........................................................................................ 4-4
4.4 Setting the SP Upper and Lower Limit Values ................................................... 4-6
Set Point Limiter ................................................................................. 4-6
Setting ................................................................................................ 4-6
4.5 Alarm Delays...................................................................................................... 4-8
Alarm Delays ...................................................................................... 4-8
Section 5 Parameters.................................................................. 5-1
5.1 Conventions Used in this Section ...................................................................... 5-2
5.2 Operation Level .................................................................................................. 5-3
5.3 Moving to the Initial Setting Level....................................................................... 5-8
5.4 Initial Setting Level(1)......................................................................................... 5-9
5.5 Initial Setting Level (2)...................................................................................... 5-14
5.6 Initial Setting Level (3)...................................................................................... 5-16
5.7 Initial Setting Level (4)...................................................................................... 5-20
5.8 Initial Setting Level (5)...................................................................................... 5-24
Appendices ................................................................................A-1
Specifications ...........................................................................................................A-2
Ratings ...............................................................................................A-2
Characteristics....................................................................................A-3
Error Displays...........................................................................................................A-4
Burnout/Short-circuit Display and Causes ...............................................................A-7
Parameter Operation Lists .......................................................................................A-8
Sensor Input Setting Range, Indication Range, Control Range.............................A-12
Setting Levels Diagram ..........................................................................................A-14
Parameter Flow......................................................................................................A-15

Table of Contents

Other manuals for Omron E5CSV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5CSV and is the answer not in the manual?

Omron E5CSV Specifications

General IconGeneral
Setting MethodDigital setting using front panel keys
Dimensions48 x 48 x 78 mm (W x H x D)
Number of Control Outputs1
Control MethodON/OFF control or PID control
Input TypesThermocouple
Supply Voltage100 to 240 VAC
Output TypeRelay or Voltage (for driving SSR)
Display7-segment digital display
Mounting MethodPanel mounting
Setting Resolution0.1 °C or 1 °C
Power Supply Voltage100 to 240 VAC
Ambient Operating Humidity25% to 85% RH
Ambient Operating Temperature-10 to 55°C (with no icing or condensation)