F3SG-SR/PG
65
Indicator
LED Indicators on Intelligent Tap
Shown below are indication statuses of LED indicators on the Intelligent Tap when you purchased.
*1. When the safety outputs of the F3SG-SR are in the ON state, the outputs of the Intelligent Tap are in the ON state.
*2. When the safety outputs of the F3SG-SR are in the OFF state, the outputs of the Intelligent Tap are in the OFF state.
Note: In the SETTING state to make settings with the SD Manager 3, the IN, OUT indicators blink. (IN: Yellow, OUT: Green)
For more information on the statuses of the LED indicators in the SETTING state, refer to User's Manual (Man.No.Z405).
Location
Indicator
Name Color Illuminated Blinking
1 IN Sensor status Yellow
Safety outputs of the F3SG-SR are in the ON
state
The F3SG-SR is in the LOCKOUT state. Or
the Intelligent Tap is waiting for Push Switch
operation (in the Backup) or the Intelligent
Tap and F3SG-SR are waiting for restart (in
the Backup). Or communication error in the
Backup or between the F3SG-SR and the
Intelligent Tap. Or the Restoration failed
2 OUT Output status
Green
Outputs of the Intelligent Tap are in the ON
state(*1)
The Restoration failed.
Or in the Restoration, the Intelligent Tap has
communication error, is waiting for Push
Switch operation or transferring data, or the
Intelligent Tap and F3SG-SR are waiting for
restart.
Red
Outputs of the Intelligent Tap are in the OFF
state (*2)
Communication error between the F3SG-SR
and the Intelligent Tap
3 IO-Link IO-Link Green ---
Intelligent Tap communicates with IO-Link
Master. Or IO-Link circuit error
4 ERR Lockout Red
The Intelligent Tap is in the LOCKOUT state,
or has communication error, DIP Switch
circuit error at startup, communication error in
the Backup or Restoration, restoration failure,
IO-Link circuit error, power supply voltage
error or other errors
---