F3SG-SR/PG
98
*1. You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
*2. Other indicators than the ERR and MAINT indicators are not illuminated. For details of the error, refer to [Code] and [Error description] displayed
in [Error Log] in the SD Manager 3.
Operating range selection setting
error
XXEB
The setting of the operating range selection may be
incorrect.
When the Intelligent Tap is connected, check if the
Operating Range Selection of the DIP Switch is
properly set.
When the Intelligent Tap is not connected, check if the
Operating Range Select Input line is properly wired.
External device monitoring error
---
*2
X52
Relay may be welded. Replace the relay.
The relay and the RESET line may not be properly wired.
Check the wiring with the relay.
The relay response time may be exceeding the allowable
delay time. Change the allowable delay time or replace the
relay with one that has an appropriate response time.
Error other than those above
---
*2
X
Error code
other than
those above
An error may have occurred in the internal circuit.
Replace the F3SG-SR.
Description
Checking by
Error code
(HEX)
*1
Cause and measures
Indicator
SD Manager 3/
SD Manager 3
Mobile APP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG-SR Series and is the answer not in the manual?

Omron F3SG-SR Series Specifications

General IconGeneral
BrandOmron
ModelF3SG-SR Series
CategorySecurity Sensors
LanguageEnglish

Related product manuals