Functions and Operations
Section 5 Functions and Operations
5-42
Previous average value comparison makes the measurement value the difference between the present
input value and the average of all previous input values.
(Vn indicates the input value and Cn indicates the comparative set value used for the next input.)
* Previous average value comparison is performed on confirmed measurement values.
• When the timing hold is set to Normal, the comparison is performed every time.
•
When the timing hold is set to a setting other than Normal, the comparison is performed on held values.
Previous average value comparison is set using the following
parameter.
Parameter Setting Procedure
Number of
measurements
Input
value
Display
value
Comparative set value for next input
1V
1 V1-V1=0 C1=V1
2V2 V2-C1
C2=(C1+V2)= (V1+V2)
3V
3 V3-C2
C3=(C2+V3)= (V1+V2)+ V3
4V4 V4-C3
C4=(C3+V4)= (V1+V2)+ V3+V4
·
·
·
·
·
·
·
·
·
·
·
·
nV
n Vn-Cn-1
Cn= (V1+V2)+ V3+···+ Vn
1
2
---
1
2
---
1
2
---
1
4
---
1
2
---
1
2
---
1
8
---
1
4
---
1
2
---
1
2
n1–
-------------
1
2
n2–
-------------
1
2
---
Parameter Set value Meaning of set value
Previous average
value comparison
hp-f
off Previous average value
comparison disabled
on Previous average value
comparison enabled
A Press the L [LEVEL] Key for at least
3 s in RUN level to move to the initial
setting level.
3 s min.
•
“
L
0
”
is displayed on the level/bank display
to indicate the initial setting level.
B Press the M [MODE] Key several times
to change the PV display to “amov.”
•
This parameter is not displayed for the
initial status due to setting level protect.
Refer to "Limiting Key Operations" (P.5-
102) for information on removing setting
level protect.
C Press the S [SHIFT] Key to make the
SV display flash.
• The setting can be changed when the
SV display starts to flash.
hp-f
L f
(HP-F)
L
Displays “L 0.”
L 0
M
amov
0
L 0
S
amov
00000