Functions and Operations
Section 5 Functions and Operations
5-96
F Press the M [MODE] Key several times
to select the comparative set value to
be changed.
G Press the S [SHIFT] Key to make the
SV display flash.
H Use the U [UP] and S [SHIFT] Keys
to change the set value.
I Press the M [MODE] Key to switch to
the next parameter.
The parameter changed in step H is
registered.
J Press the M [MODE] Key several times
to change the PV display to “copy.”
K Press the S [SHIFT] Key to make the
SV display flash.
L Use the U [UP] Key to change the set
value.
M Press the M [MODE] Key to switch to
the next parametersv.
bnk.”
M
sv1. h
99999
L 4
S
sv1. h
99999
L 4
SU
sv1. h
10000
L 4
M
sv1. l
-19999
L 4
Repeat steps F to I to
change other comparative
set values in the same bank.
The settings for all
comparative set values in the
bank have been completed.
Proceed to step
J to copy the
contents of this
bank to all
banks.
Proceed to step
D to set
comparative set
values for other
banks.
Proceed to step N
when bank
comparative set
value settings have
been completed.
M
copy
off
L 4
S
copy
off
L 4
U
on
L 4 copy
M
sv. bnk
0
L 4

Table of Contents