Functions and Operations
Knowledge Required for Setting Parameters
5-5
Advanced Function
Setting Level
A special operation is required to move to the advanced function
setting level. Use the following procedure.
Procedure
The Setting Level Protect setting must be set to 0 (set.pt=0) to
enable moving to the advanced function setting level.
The advanced function setting level will be entered if the password
is correct.
If the password is incorrect, the first parameter on the initial setting
level will be displayed.
A Move to the initial setting level, press the M [MODE] Key several
times to display the “amov” (move to advanced function setting
level) parameter.
B Press the S [SHIFT] Key to enable entering the password.
C Use the S [SHIFT] and U [UP] Keys to set the password.
The password is “-0169” (-0169).
D Press the M [MODE] Key to write the password.
Move to the advanced function setting level.
The set value is always 0 after moving
from character display to monitor status.
(Does not move to the advanced function setting level.)
To next parameter
Advanced function setting level
Set value initialization
Password doesn't match.
Password matches.
Change status
amoV
amoV
0
0
f
init
Use the
S
[SHIFT]
and
U
[UP] Keys
to set the password.