EasyManua.ls Logo

Omron M1 Series - Page 261

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
E131
Frequency Calculation
Operation T
arget 1
0: Up/Down keys on Operator
1: Voltage input to terminal
[AI1]
2: Current input to terminal
[AI2](AII)
3: Voltage input to terminal
[AI2](AIV)
5: Pulse train input
6: RS-485 communication
7: Fieldbus (Reserved)
1
- -
page
7-118
E132
Frequency Calculation
Operation Target 2
0: Up/Down keys on Operator
1: Voltage input to terminal
[AI1]
2: Current input to terminal
[AI2](AII)
3: Voltage input to terminal
[AI2](AIV)
5: Pulse train input
6: RS-485 communication
7: Fieldbus (Reserved)
2
- -
page
7-118
E133
Frequency Calculation
Operator Selection
0: Addition (E131 + E132)
1: Subtraction (E131 - E132)
2: Multiplication (E131 x E132)
0 - -
page
7-118
E134
Frequency Addition
Amount
0.00 to 590.00 Hz
0.00 - Hz
page
7-118
E135
Frequency Addition
Sign Selection
0: Frequency command +
E134
1: Frequency command -
E134
0 - -
page
7-118
E139
Overvoltage/Overcur-
rent Restart Function
Selection
0: Trip immediately
4: Restart at the frequency se-
lected by E152
0 - -
page
7-58
4 Parameter List
4-95
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-2 Parameter E (Terminal Functions)

Table of Contents

Related product manuals