Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
H45 Mock Alarm
0: Disable
1: Enable (Generate mock
alarm)
0
Availa-
ble
- page 3-3
H46
Auto Search Delay
Time 2 for Starting
Mode
0.1 to 100.0 s
1.0
Availa-
ble
s
page
7-49
H47
Main Circuit Capacitor
Service Life Coeffi-
cient (Initial Value)
0: Start measurement
1: Measurement failure
2 to 65535: Measurement val-
ue
0
Availa-
ble
-
page
7-96
H48
Cumulative Run Time
of Capacitors on Print-
ed Circuit Boards
0 to 9,999 (in 10 hours)
0
Availa-
ble
10
hex
page
7-100
H49
Auto Search Delay
Time 1 for Starting
Characteristic
0.0 to 10.0 s
0
Availa-
ble
s
page
7-49
H54
Jogging Acceleration
Time
0.00 to 6000 s
6.00
Availa-
ble
s
page
5-60
H55
Jogging Deceleration
T
ime
0.00 to 6000 s
6.00
Availa-
ble
s
page
5-60
H56
Deceleration Time for
Forced Stop
0.00 to 6000 s
6.00
Availa-
ble
s
page
7-152
H57
S-curve Acceleration
Range Frequency at
Starting
0 to 100 %
10
Availa-
ble
%
page
5-40
H58
S-curve Acceleration
Range Frequency at
End
0 to 100 %
10
Availa-
ble
%
page
5-40
H59
S-curve Deceleration
Range Frequency at
Starting
0 to 100 %
10
Availa-
ble
%
page
5-40