-20,000 = B1E0 hex →
B1Hex E0Hex
Example: Frequency Reference (S01) = 20,000 (= 100% = Maximum output frequency)
20,000 = 4E20 hex →
4EHex 2
0Hex
Data Format [35]: ROM Version
Setting range: 0 to 59,999
Example: ROM Version (M25) = 0064 hex
00Hex 6
4Hex
→ 0064 hex = 100
Data Format [37]: Floating Point Data (Load Shaft Speed, etc.)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Exponent
part
Mantissa part
Exponent part: 0 to 3, Mantissa part: 1 to 9,999
V
alue represented in this format = Mantissa part × 10 to the power of (exponent part - 2)
Value Mantissa part Exponent part 10 to the power of (exponent part - 2)
0.01 to 99.99 1 to 9,999 0 0.01
100.0 to 999.9 1,000 to 9,999 1 0.1
1,000 to 9,999 1,000 to 9,999 2 1
10,000 to 99,990 1,000 to 9,999 3 10
Example: Rotate Speed Monitor (W08) = 99,990 r/min
99,990 = Mantissa part: 9,999 (270F hex), Exponent part: 3 = E70F hex →
E7Hex 0
FHex
Example: Rotate Speed Monitor (W08) = 9,999 r/min
9,999 = Mantissa part: 9,999 (270F hex), Exponent part: 2 = A70F hex →
A7Hex 0
FHex
Example: Rotate Speed Monitor (W08) = 9.999 r/min
999.9 = Mantissa part: 9,999 (270F hex), Exponent part: 1 = 670F hex →
67Hex 0
FHex
Example: Rotate Speed Monitor (W08) = 99.99 r/min
99.99 = Mantissa part: 9,999 (270F hex), Exponent part: 0 = 270F hex →
27Hex 0
FHex
Data Format [41]: Alarm History
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Number of consecutive occurrences
of the same alarm
Alarm code*1
*1
: For alarm codes, refer to “Data Format [10]: Alarm Code” in this section.
This gives the contents of the alarm that occurred and the number of consecutive occurrences of the
alarm.
8 Communications Functions
8-42
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C