Parameter
No.
MODBUS ad-
dress (MSB)
MODBUS ad-
dress (LSB)
Parameter name
Communica-
tion data for-
mat (during
single-word
access)
Communica-
tion data for-
mat (during
double-word
access)
F12 300Eh -
1st Motor Electronic Thermal
Time Constant
3 -
F14 3010h -
Power Interruption Restart
Mode Selection
1 -
F15
124Eh 124Fh 1st Frequency Upper Limit 5 5
F16 1250h 1251h 1st Frequency Lower Limit 5 5
F18 3016h -
Input Terminal [AI1, AI2] Bias
for 1st Frequency Command
6 -
F20 3018h -
1st DC Injection Braking Start
Frequency
3 -
F21 3019h - 1st DC Injection Braking Level 1 -
F22 301Ah - 1st DC Injection Braking Time 5 -
F23 301Bh - 1st Starting Frequency 3 -
F24 301Ch -
1st Starting Frequency 1
Holding T
ime
5 -
F25 301Dh -
1st Stop Frequency 3 -
F26 301Eh - Carrier Frequency 1 -
F27 301Fh - Motor Sound Tone 1 -
F29 3021h -
Output Terminal [AO] Mode
Selection
1 -
F30 3022h - Output Terminal [AO] Gain 1 -
F31 3023h -
Output Terminal [AO] Function
Selection
1 -
F33 3025h -
Output Terminal [AO] Pulse
Rate (PO)
1 -
F37 3029h -
1st V/f Characteristics Selec-
tion
1 -
F38 302Ah -
1st Stop Frequency Detection
Method Selection
1 -
F39 302Bh -
1st Stop Frequency Holding
T
ime
5 -
F40 132Ah -
Torque Limit 1 1 -
F41 132Bh - Torque Limit 2 1 -
F42 302Eh - 1st Drive Control Selection 1 -
F43 302Fh -
1st Overload Protect Function
Selection
1 -
F44 3030h - 1st Overload Protect Level 1 -
F50 3036h -
Electronic Thermal for Braking
Resistor Discharging Capacity
1 -
F51 3037h -
Electronic Thermal for Braking
Resistor Allowable A
verage
Loss
45 -
F52 3038h -
Braking Resistor Resistance 12 -
F58 303Eh - Output Terminal [AO] Filter 5 -
F59 303Fh - Output Terminal [AO] Bias 4 -
F80 3054h - Load Mode Selection 1 -
8 Communications Functions
8-48
M1 Series Standard Type User's Manual (I669)