193
Command, function and parameter description Section 6-3
In the following example, the value 1.2555 is placed into VR variable 15. The
local variable
val
is used to name the global variable locally:
val = 15
VR(val) = 1.2555
Example 2
A transfer gantry has 10 put down positions in a row. Each position may at
any time be full or empty. VR(101) to VR(110) are used to hold an array of ten
1s and 0s to signal that the positions are full (1) or empty (0). The gantry puts
the load down in the first free position. Part of the program to achieve this
would be as follows:
movep:
MOVEABS(115) Move to first put down position
FOR VR(0) = 101 TO 110
IF (VR(VR(0)) = 0) THEN GOSUB load
MOVE(200) 200 is spacing between positions
NEXT VR(0)
PRINT "All positions are full"
WAIT UNTIL IN(3) = ON
GOTO movep
load: Put load in position and mark array
OP(15,OFF)
VR(VR(0)) = 1
RETURN
The variables are backed up by a battery so the program here could be
designed to store the state of the machine when the power is OFF. It would of
course be necessary to provide a means of resetting completely following
manual intervention.
Example 3
loop: Assign VR(65) to VR(0) multiplied by
axis 1 measured position
VR(65) = VR(0)*MPOS AXIS(1)
PRINT VR(65)
GOTO loop
6-3-200 WA
Type: System Command
Syntax: WA(
time
)
Description: The WA command pauses program execution for the number of milliseconds
specified for time. The command can only be used in a program.
Arguments:
time
The number of milliseconds to hold program execution.
Example: The following lines would turn ON output 7 two seconds after turning OFF out-
put 1.
OP(1,OFF)
WA(2000)
OP(7,ON)
6-3-201 WAIT IDLE
Type: System Command
Syntax: WAIT IDLE
Description: The WAIT IDLE command suspends program execution until the base axis
has finished executing its current move and any buffered move. The com-
mand can only be used in a program.