Through-beam Sensor Heads: FUN Mode Functions
Section 3-8
101
l Default Settings
The settings are initialized to the default setting made at the factory. The
default settings are listed in the following table.
Refer to 4-5-8 Initializing Settings.
Mode Function Initial value
FUN Scaling values OFF
Number of samples to aver-
age
32 samples
Hysteresis 0.5% of full scale (FS)
Hold OFF (disabled)
Timer OFF (disabled)
Two-sensor operation (when
two Amplifier Units are con-
nected)
OFF (disabled)
Special selection CLOSE
Monitor focus function 4 V (20 mA): Maximum sensing dis-
tance
−4 V (4 mA): Minimum sensing dis-
tance
Differentiation function OFF (disabled)
Display reverse function OFF (disabled)
ECO display function OFF (disabled)
Limited number of display
digits
All digits displayed
Settings for non-measure-
ment
KEEP
Zero reset memory function ON
Gain switch METAL
Auto-scale value 100-L
T H threshold value 100.00
L threshold value 0.00
RUN Sub-display function Threshold values
Reference incident level set-
ting
Not set
Zero reset function OFF (invalid)