EasyManua.ls Logo

Omron ZX Series - Other Special FUN Mode Settings

Omron ZX Series
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FUN (Function) Mode Section 4-5
138
4-5-12 Other Special FUN Mode Settings
The following “other” items can be set when or is selected
in the special FUN mode settings
Settings for
non-measurement
Zero reset memory
function
Gain setting
Output value held
Current: About 23 mA
Voltage: Clamped at
about 5.5 V (fix
ed)
Go to the next
mode.
Enabled
Disabled
Black mode
White mode
Metal mode
Auto (See note.)
Note: This function can be set only for a
Reflective Sensor.