EasyManuals Logo

Omron ZX Series User Manual

Omron ZX Series
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
FUN (Function) Mode Section 4-5
124
4-5 FUN (Function) Mode
4-5-1 Normal Operation
The Function Mode is used to set various functions. Basic procedures for
setting items are described in the next section.
In RUN Mode, outputs are made in Function Mode in the KEEP status
regardless of the KEEP/CLAMP setting for non-measurement.
4-5-2 Changing the Function
The basics of changing the function are as follows:
The RIGHT Key changes to the next item (forward).
The LEFT Key changes to the previous item (backward).
Set the mode switch to FUN.
Change the function by pressing either
the RIGHT (forward) or LEFT (back-
ward) Key.
RUN T FUN
The current set value will be displayed
on the sub-display.
Pressing the RIGHT Key
changes the function for-
ward.
Example: Changing the Function Forward

Table of Contents

Other manuals for Omron ZX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ZX Series and is the answer not in the manual?

Omron ZX Series Specifications

General IconGeneral
Power Supply Voltage12 to 24 VDC ±10%
Protection RatingIP67
Output TypeNPN or PNP
Protection CircuitReverse polarity protection, short-circuit protection
Operating Temperature-25 to 55°C (-13 to 131°F)