Reflective Sensor Heads: FUN Mode Functions
Section 3-5
69
3-5-11 Display Reverse Function
The display direction of the digital displays can be selected. Select either
forward or backward according to the mounting direction of the Amplifier
Unit.
Refer to 4-5-11 Special FUN Mode Settings Related to Dis-
plays.
3-5-12 ECO Display Function
The ECO display function can be enabled or disabled. When the ECO dis-
play function is enabled, the digital display will not light.
3-5-13 Limiting the Number of Display Digits
The number of display digits of the main display and sub-display can be
set. When the number of digits is reduced, the rightmost digit is disabled
first. In addition, if 0 digits are specified, the entire digital display will be dis-
abled. This applies, however, only in RUN Mode.
3-5-14 Setting for Non-measurement
The output method used during non-measurement can be set. This setting
applies when a reset is input or a reception error occurs.
Maximum output voltage: Approximately 5.5 V
Maximum output current: Approximately 23 mA
Refer to 4-5-12 Other Special FUN Mode Settings.
Outputs Setting for non-measurement
CLAMP KEEP
Judgement outputs All OFF. The status immediately
before measurement
stopped is held.
Linear output Held at the maximum
output value.

Table of Contents

Other manuals for Omron ZX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ZX Series and is the answer not in the manual?

Omron ZX Series Specifications

General IconGeneral
Power Supply Voltage12 to 24 VDC ±10%
Protection RatingIP67
Output TypeNPN or PNP
Protection CircuitReverse polarity protection, short-circuit protection
Operating Temperature-25 to 55°C (-13 to 131°F)