EasyManua.ls Logo

Omron ZX Series - Page 123

Omron ZX Series
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Through-beam Sensor Heads: FUN Mode Functions
Section 3-8
103
Examples: Monitor Focus 2
Examples: Monitor Focus 3, Enabling Differentiation
4
4
Sensor display value
(mm)
Sensor display value
(mm)
Sensor display value
(mm)
0
5.0
For these settings:
For these settings:
4
4
4
Linear output voltage
Linear output voltage
Linear output
voltage
(V)
(V)
(V)
3
2
4
0 1.25 3.75 5.0
0 0.625 3.75 5.0
1.25 mm: 4 V
3.75 mm: 4 V
0.625 mm: 3 V
3.75 mm: 2 V
20
20
18
12
0 2.5 3.75 5.0
Linear output
current
(mA)
Linear output
current
(mA)
4
4
Sensor display value
(mm)
Sensor display value
(mm)
0 2.5
5.0
For this setting:
12
3.75 mm: 18 mA