EasyManuals Logo

Omron ZX Series User Manual

Omron ZX Series
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
FUN (Function) Mode Section 4-5
130
n Errors when Confirming a Numeric Value
A setting error will occur under the following conditions.
1. When the set value is too large.
2. When the set value is too small.
If an error occurs, the relevant error will be displayed on the sub-display
three times at one-second intervals as shown in the following figure, and
then the previous set value will be displayed.
The error is displayed when the ENT Key is pressed.
1. Errov (Error: Over) 2. ErrUd (Error: Under)

Table of Contents

Other manuals for Omron ZX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ZX Series and is the answer not in the manual?

Omron ZX Series Specifications

General IconGeneral
Power Supply Voltage12 to 24 VDC ±10%
Protection RatingIP67
Output TypeNPN or PNP
Protection CircuitReverse polarity protection, short-circuit protection
Operating Temperature-25 to 55°C (-13 to 131°F)