loss warning would be replaced by a Paused field, with the date and time of the
pause event.
TX1 also allows the resumption of imaging jobs that failed for the following reasons:
Source drive missing or disconnected
Destination drive missing or disconnected
Destination drive full
These types of failed jobs can be resumed through either the Recent jobs area in the
Jobs tab or the job's log details screen, as described in the sections above. The best
way to tell if a job is resumable or not is to check for the ability to resume it from the
Recent jobs list or in the log details screen.
Note: For each of these situations, the exact same source and destination drives
are required before the job can be resumed. In the case of a full destination
drive, other files (unrelated to the in-progress job) must be deleted from the
drive before the job can be resumed.