ELE-51
4. Confirm that the value difference between
USER DATA and DEFAULT DATA is less than
+/- 0.01 in case of first time use, or changed PC,
Tools, or A/D board.
5. Confirm that the value difference using the
same RF Auto Adjustment Tool, PC and A/D
Board combination is less than +/- 0.003.
If the USER DATA value is out of range, RF
Auto Adjustment Tool may defective.
6. If USER DATA value is in the range, the
message "Normalizing Again ?" will appear,
then select "N". After selection, the following
message will appear
Please Select (U)ser / (D)efault!
Select "U".
Eject the tape after Main Menu appeared on the
monitor.
14-5. PB Circuit Adjustment
1. Select "2 Adjust Menu" from Main Menu so that
the display will change to "Error Rate Data" and
adjustment menu will appear.
2. Select "1. USER DEF" after adjustment menu
appeared.
* If select "1. USER DEF"
PB Circuit --> REC circuit Adjustment
continuously.
3.
Next, the message “DECK No INPUT?” will
appear on the Command>> display part of
bottom of the monitor. Input serial No. or optional
code and press Enter key.
* Input No. will be used for discrimination of
adjustment data and error rate data.
4. Next, the message "Please Insert 25M Master
Tape" will appear on the Command>> display
part of bottom of the monitor.
Insert a 25M Color-Bar Master Tape.
(VFM3580KM for NTSC, VFM3680KM for PAL)
5.
RF Auto Adjustment will start as shown below.
(Do not touch camcorder and PC during Auto
Adjustment)
<<Adjustment Flow>>
1. PB Adjustment ! 2. REC Adjustment
6.
6. After completion of PB circuit adjustment, REC
circuit adjustment will start.