ELE-31
6-3. Flare Compensate Adjustment
BOARD
CAM SYSCON
TP
VIDEO OUT (75 ohm termination)
ADJUST
EVR
F.NUMBER
See Below
CHART
Flare Chart
M. EQ.
WFM
SPEC.
Black Level : R = G = B
1. Set the
EVR
as shown below.
COM:[1E] DATA:[27] ADR:[00] [Enter]
2. Set
the
WHITE BAL SW
to
A
position and
execute
AWB
,
ABB,
and
AWB
again.
<Note>
When operate AWB, connect a Waveform Monitor
to
the
VIDEO OUT
and set Iris so that the peak level is
80%
.
3. Connect a Waveform Monitor to the
VIDEO OUT
and set Iris so that the peak level is
100%
. Then
open the Iris 1.5 stop from the 100% position.
Ex.)
F11
F8-1/2 , F11-1/2
F5.6
4. Change the R, G and B at the VIDEO OUT by
EVR
and measure the each level
5. Find the lowest level of them and adjust other 2
level so that they are equal to the lowest level.
The EVR Variable Data range is
00h-64h
,
The level is not changed over 64h.
R /G / B channel measurement and adjustment
[ Rch ]
(1)
COM:[1E] DATA:[32] ADR:[00] [Enter]
(2)
COM:[0E] DATA:[00] ADR:[0B] [Enter]
(3) Adjust by
[
]/[
!
].
[ Gch ]
(1)
COM:[1E] DATA:[33] ADR:[00] [Enter]
(2)
COM:[0E] DATA:[00] ADR:[0C] [Enter]
(3) Adjust by
[
]/[
!
].
[ Bch ]
(1)
COM:[1E] DATA:[34] ADR:[00] [Enter]
(2)
COM:[0E] DATA:[00] ADR:[0D] [Enter]
(3) Adjust by
[
]/[
!
].
100%
R G B
Ex.) Rch level is lowest, so adjust G
and B levels equal to the Rch level.