EasyManua.ls Logo

Panasonic AJ-D610WBP - Option Menu Screen

Panasonic AJ-D610WBP
363 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INF-23
9-3. Option Menu Screen
[Option Menu 1 Screen]
< OPTION MENU 1>
ENG SECURITY : OFF
TC OUT : TCG
BATT WARNING : ON
TAPE WARNING : 3min
MIC POWER INH : OFF
BATT REMAIN(F) : 70%
TAPE REMAIN : 3min
CUE SELECT : SW
V BLANKING : 20H
SAVE LED : SAVE
ITEM RANGE PRESET REMARK
ENG SECURITY ON/OFF OFF
OFF : Engineer, Service and Design menu can be opened.
ON : Engineer, Service and Design menu can not be opened.
To open those menus turn Power SW OFF under the
condition the CAM/BAR SW set to BAR side and then
AWB/ABB SW set to ABB side, turn POWER SW ON all
menus can be open.
TC OUT TCG,TCG/TCR TCG
TCG : TCG signal always output
TCG/TCR : TCR signal output in V-V mode and TCG signal
output in E-E mode.
BATT WARNING ON/OFF ON
ON : When the unit becomes BATT NEAR END condition,
ALARM and TALLY lamp are flashing.
OFF : When the unit becomes BATT NEAR END condition,
ALARM and TALLY are not flashing.
TAPE WARNING 3min/2min 3min
ON : When the unit becomes BATT NEAR END condition,
ALARM and TALLY lamp are flashing.
OFF : When the unit becomes BATT NEAR END condition,
ALARM and TALLY lamp are not flashing.
MIC POWER INH
(PAL MODEL ONLY)
ON/OFF OFF
MIC POWER SW SETTING
ON : MIC POWER SW is always OFF.
OFF : MIC POWER SW can be setting by Side panel.
BATT REMAIN (F) 70%/100% 70%
The way to battery remains display. (LCD PANEL)
70% : MAX70% display.
100% : MAX100% display.
TAPE REMAIN 3min/5min 5min
The way to tape remains display. (LCD PANEL)
3min : Display to 3min / scale
5min : Display to 5min / scale
CUE SELECT
SW/CH1/CH2/
MIX
SW
Select the CUE audio sources.
SW : Normal mode (Can be select the side panel sw)
Other : Mode is Fixed to your selected item.
V BLANKING 20H/21H 20H
Setting for V Blanking position.
Role addition to the “VTR SAVE” indicator. (On the VF)
SAVE LED SAVE/S.&TAPE S.&TAPE
SAVE
S.&TAPE
: Normal mode ( SAVE / STBY SW position
displayed )
: Tape remain warning (By LED Flashing) in additions to
Normal mode.

Table of Contents