ELE-30
6. CAMERA SYSCON
6-1. White Shading Adjustment
BOARD
CAM SYSCON
TP
TP302[G] (PRE PROCESS)
CAM OUT (75 ohm termination)
ADJUST
EVR
CHART
Light Box (Spherical type)
Distance Aprox.50cm, Defocus
SHUTTER
1/250
M. EQ.
Monitor TV, WFM, Vector Scope
SPEC.
Monitor
WFM
Vector Scope
:No colored
:Flat
: Dot is circle and cross on
the origin
Set the Camera recorder switches and M.EQ. settings
as shown below.
Vector scope : X10 mode
Camera Aspect : 16:9 mode
Normal setting
1. Set a lens extender
X1
condition.
2. Set the EVR as shown below.
COM:[1E] DATA:[30] ADR:[00] [Enter]
3. Connect a WFM to
CAM OUT
and set Iris so that
the peak level is
80%
.
4. Set
the
WHITE BAL SW
to
A
position and operate
AWB
, then operate
ABB to AWB
.
5. Set the EVR as shown below.
(Execute the WHITE SAHDING)
COM:[1E] DATA:[31] ADR:[00] [Enter]
6. Confirm the each signals condition is in the
specification.
With Lens Extender setting
7. Set a lens extender
X2
condition.
8. Connect a WFM to
CAM OUT
and set Iris so that
the peak level is
80%
.
9. Set
the
WHITE BAL SW
to
A
position and operate
AWB
, then operate
ABB to AWB
.
10. Set the EVR as shown below.
(Execute the WHITE SAHDING)
COM:[1E] DATA:[31] ADR:[00] [Enter]
11. Confirm the each signal condition is in the
specification.
With Ratio converter setting
12. Set a lens extender
X1
condition. Then set a lens
ratio converter
X0.8
condition.
13. Connect a WFM to
CAM OUT
and set Iris so that
the peak level is
80%
.
14. Set
the
WHITE BAL SW
to
A
position and operate
AWB
, then operate
ABB to AWB
.
15. Set the EVR as shown below.
(Execute the WHITE SAHDING)
COM:[1E] DATA:[31] ADR:[00] [Enter]
16. Confirm the each signal condition is in the
specification.
<Note>
While White Shading is operating * mark is displayed
on the EVF.
6-2. Digital Dark Shading
Adjustment
BOARD
CAM SYSCON
TP
CAM OUT (75 ohm termination)
ADJUST
EVR
F.NMBER
-
M. EQ.
Monitor TV, WFM
SPEC.
Monitor
WFM
:No colored
:Flat
1. Set WHITE BAL to PRE.
2. Set the EVR as shown below.
COM:[1E] DATA:[2B] ADR:[00] [Enter]
3. Set the EVR as shown below.
(Digital Dark Shading Operation)
COM:[1E] DATA:[2D] ADR:[00] [Enter]
4. Confirm the following items.
Monitor: No colored in black (should be
normal picture)
WFM: Flat
[
WFM ( V Rate) ]
FLAT
FLAT
80%
[ WFM ( V rate) ]
[ Vector Scope ]
Origin
[ WFM (H rate) ]
FLAT
80%