ELE-23
4-6. SYSTEM PHASE Adjustment
(2)
BOARD
SYNC
TP
CAM OUT
ADJUST
VR3103 [SYSTEM H PHASE]
INPUT
Composite Color Bar signal
(GENLOCK IN)
MODE
Camera Bar
M. EQ.
SCH meter
SPEC.
See below
1. Set the SCH meter at EXT Mode.
2. Precise adjust the
VR3103
so that the Burst
phase of GENLOCK IN is same as CAM OUT
signal.
<NTSC>
<PAL>
4-7. SYSTEM PHASE Adjustment
(3)
BOARD
SYNC
TP
CAM OUT
ADJUST
VR3001 [BURST PHASE], EVR
INPUT
Composite Color Bar signal
(GENLOCK IN)
MODE
Camera Bar
M. EQ.
SCH meter
SPEC.
See below
1. Set the SCH meter at EXT Mode.
2. Set the EVR as shown below.
COM:[1E] DATA:[1C] ADR:[00] [Enter]
3. Adjust the
VR3001
so that the Burst phase of
GENLOCK IN is same as CAM OUT signal.
<NTSC>
<PAL>
BURST
H
BURST
H