Chapter 4Settings — [PROJECTOR SETUP] menu
ENGLISH - 201
[NUMBER OF REGISTERED
SIGNAL]
Displays the number of registered signals.
[COOLING CONDITION] Displays the set cooling conditions.
[ATMOSPHERIC PRESSURE] Displays the atmospheric pressure.
[REMOTE2 STATUS] Displays the control status of the REMOTE2.
[AC VOLTAGE] Displays the input supply voltage.
[LENS TYPE]
*2
Displays the type name (type of the projection lens) set to the projection lens.
[LENS ID]
*2
Displays the ID set to the projection lens.
[LENS NAME]
*2
Displays the name set to the projection lens.
[LENS THROW RATIO]
*2
Displays the range of the throw ratio supported by the projection lens.
[LENS ZOOM TYPE]
*2
Displays the drive method of the zoom motor attached to the projection lens.
[ZOOM CALIBRATION]
*2
Displays the zoom calibration result ([OK]/[FAILED]) and the calibration date.
[ON COUNT]
[POWER ON TIMES] Displays the number of times the power is turned on.
[MECHANICAL SHUTTER]
Displays the number of times the mechanical shutter is closed.
It is counted when [MECHANICAL SHUTTER] is set to [ENABLE].
[OPERATING MODE]
Displays the setting value of the [PROJECTOR SETUP] menu [OPERATION SETTING]
[OPERATING MODE].
[NORMAL] Displays the runtime of the light source with [OPERATING MODE] set to [NORMAL].
[ECO] Displays the runtime of the light source with [OPERATING MODE] set to [ECO].
[QUIET] Displays the runtime of the light source with [OPERATING MODE] set to [QUIET].
[USER1] Displays the runtime of the light source with [OPERATING MODE] set to [USER1].
[USER2] Displays the runtime of the light source with [OPERATING MODE] set to [USER2].
[USER3] Displays the runtime of the light source with [OPERATING MODE] set to [USER3].
[CONSOLIDATED RUNTIME]
*3
Converts the total runtime of the light sources with [OPERATING MODE] set to each item into the
time used with the [NORMAL] setting.
The consolidated runtime is used for a rough indication about when to perform maintenance when the
projector is used in combination of each item in [OPERATING MODE].
[UPGRADE KIT] [ET-NUK10]
Displays the activation status by the NFC Upgrade Kit (Model No.:
ET-NUK10).
Or, displays the status of the NFC function.
[ACTIVATED]: The NFC function can be used.
[NOT ACTIVATED]: The NFC function cannot be used.
[SLOT]
Displays the product model number of the Function Board installed in <SLOT>.
Also, the rmware version is displayed after the product model number.
[SIGNAL INFORMATION]
[INPUT]
Displays the input used for the projected image.
Displays the representative input terminal when one image is
displayed with multiple input signals.
[SIGNAL FORMAT] Displays the format of the input signal.
[LINK]
Displays whether the input signal is a single link or quad link when
the image is displayed with SDI input.
[2D/3D] Displays the determination results of the 2D/3D display.
[SIMUL]
Displays the [3D SIMUL INPUT SETTING] setting.
Displays the determination result of the signal when [AUTO] is set.
[4K DIVISION]
Displays the [4K DIVISION] setting.
Displays the determination result of the signal when [AUTO] is set.
[SAMPLING]
Displays the sampling information and the color format of the input
signal.
[BIT DEPTH] Displays the gradation of the input signal.
[SIGNAL LEVEL] Displays the signal level of the input signal.
[GAMMA] Displays the [GAMMA] setting.
[COLOR SPACE] Displays the [COLOR SPACE] setting.
*1 The temperature status is indicated with text color (green/yellow/red) and bar scale. Use the projector within the range that the indication is
green.
*2 This is displayed only when the standard DC motor unit installed in the Zoom Lens (Model No.: ET-D75LE6, ET-D75LE8, ET-D75LE10,
ET-D75LE20, ET-D75LE30, ET-D75LE40) is replaced with the stepping motor unit using the Stepping Motor Kit (Model No.: ET-D75MKS10),
or when a projection lens with the stepping motor is attached.
*3 [CONSOLIDATED RUNTIME] can be obtained with the following calculation formula. Values obtained by the calculation formula contain a
slight error.
Conversion formula for [CONSOLIDATED RUNTIME]
A x 1.0 + B x 0.8
f A: Runtime of the light source with [OPERATING MODE] set to [NORMAL], [QUIET], [USER1], [USER2], or [USER3]
f B: Runtime of the light source with [OPERATING MODE] set to [ECO]