Chapter 3Basic Operations — Projecting
ENGLISH - 89
3) Check the focus at the center of the image again and make fine adjustments.
4) Tighten the lock screw.
f Periphery focus adjustment ring is xed.
Note
f When the projector is used for the rst time or when the projection lens is replaced, conrm that the setting in the [PROJECTOR SETUP]
menu [LENS] [LENS TYPE] is appropriate, and then execute the [PROJECTOR SETUP] menu [LENS] [LENS CALIBRATION].
f The projection distance (THROW.DISTANCE) displayed in the periphery focus adjustment ring is an approximate guide.
Conrming the lens type
When the projector is used for the rst time or when the projection lens is replaced, conrm the [LENS TYPE]
setting. Change the setting if the type is different from the projection lens attached to the projector.
1) Press the <MENU> button.
f The [MAIN MENU] screen is displayed.
2) Press as to select [PROJECTOR SETUP].
3) Press the <ENTER> button.
f The [PROJECTOR SETUP] screen is displayed.
4) Press as to select [LENS].
5) Press the <ENTER> button.
f The [LENS] screen is displayed, allowing to conrm the current setting in [LENS TYPE].
f To change the setting, proceed to Step 6).
6) Press as to select [LENS TYPE].
7) Press the <ENTER> button.
f The [LENS TYPE] screen is displayed.
8) Press as to select the lens type.
f Select the type of projection lens attached to the projector.
9) Press the <ENTER> button.
Note
f For details of operation, refer to the [PROJECTOR SETUP] menu [LENS] [LENS TYPE] (x page 166).
Executing the lens calibration
Detect the lens adjustment limit value, and perform the calibration in the adjustment range. Execute the lens
calibration after attaching the projection lens.
Always execute the zoom calibration especially after attaching the Zoom Lens with the stepping motor.
Zoom Lens with the stepping motor
This section describes the operating procedure when the standard DC motor unit installed in the Zoom Lens
(Model No.: ET-D75LE6, ET-D75LE8, ET-D75LE10, ET-D75LE20, ET-D75LE30, ET-D75LE40, etc.) is replaced
with the stepping motor unit using the Stepping Motor Kit (Model No.: ET-D75MKS10), or when the Zoom Lens
with the stepping motor (Model No.: ET-D3LEW60, ET-D3LET80, ET-D3LEW10, ET-D3LES20, etc.) is attached.
1) Press the <MENU> button.
f The [MAIN MENU] screen is displayed.
2) Press as to select [PROJECTOR SETUP].
3) Press the <ENTER> button.
f The [PROJECTOR SETUP] screen is displayed.
4) Press as to select [LENS].
5) Press the <ENTER> button.
f The [LENS] screen is displayed.