OBJECT DESCRIPTION
INDEX
605Bh
Name
Shutdown option code
Object Code
VAR
Data Type
INTEGER16
Category
Optional
ENTRY DESCRIPTION
Access
rw
PDO Mapping
No
Value Range
INTEGER16
Default Value
0
DATA DESCRIPTION
Value
Description
-32768 ... –1
manufacturer specific
0
Disable drive function
1
Slow down with slow down ramp; disable of the drive function
2 ... 32767
reserved
12.1.2.4 Object 605Ch: Disable operation option code
The parameter disable operation option code determines what action should be taken if there
is a transition OPERATION ENABLE SWITCHED ON. OBJECT DESCRIPTION
INDEX
605Ch
Name
Disable operation option code
Object Code
VAR
Data Type
INTEGER16
Category
Optional
ENTRY DESCRIPTION
Access
rw
PDO Mapping
No
Value Range
INTEGER16
Default Value
1
DATA DESCRIPTION
Value
Description
-32768 ... -1
manufacturer specific
0
Disable drive function
1
Slow down with slow down ramp and then disabling of the drive function
2 ... 32767
reserved