Parker Hannifin Manufacturing Srl user’s manual TPDM
20 Appendix H: EtherCAT option
LED
D1
Error
Status
The EtherCAT communication of the
device is in working condition.
Booting error was detected. INIT state
reached, but parameter “Change” in
the AL status register is set to 0x01:
General Configuration Error.
state change
Slave device application has changed
the EtherCAT state autonomously:
parameter “Change” in the AL status
register is set to 0x01: change/error.
watchdog
An application watchdog timeout has
occurred.
A PDI watchdog timeout has occurred
D2
Run
Status
The device is in state INIT
The device is in state PRE-
OPERATIONAL
The device is in state SAFE-
OPERATIONAL
The device is in state
OPERATIONAL
bootstrap
The device is booting and has not yet
entered the INIT state, or the device is
in state BOOTSTRAP. Firmware
download operation in progress
Selectors
Address selector “alias”. Digit less significant
Address selector “alias”. Digit more significant
Connections
(*) use a direct cable shielded in 5 category [Standard CAT5 cable shielded, without
“crossover”], in according to the standard EtherCAT: EtherCAT Technology Group