Parker Hannifin Manufacturing Srl user’s manual TPDM
15
3 Main hardware features
3.1 Ambient conditions
temperature
operation (*)
Class 3K3, 0 … +40 °C (+32 …+104 °F)
storage
Class 1K4, -25 … +55 °C (-4 …+131 °F)
transportation
Class 2K3, -25 … +70 °C (-13…+158 °F)
humidity
operation
Class 3K3, 5-85 % without ice and condensation
storage
Class 1K3, 5-95 % without ice and condensation
transportation
Class 2K3, 95% at 40°C
altitude (**)
1000 m slm ( 3281 feet asl)
Protection degree
IP20 (only in close electric cabinet)
UL open type equipment
Pollution degree
2 or lower (no conductive dust allowed)
(*) up to +45°C (113°F)
(**)For higher installation altitude, derate the output current by 1.5% each 100m up to 2000m
maximum
3.2 Vibrations and shocks
Vibration
(IEC/EN 61800-5-1)
frequency [Hz] amplitude [mm] acceleration [m/s
2
]
operation
(3M1 class)
2 f < 9
0,3
-
9 f < 200
-
1
transportation
(2M1 class)
2 f < 9
3,5
-
9 f < 200
-
10
200 f < 500
-
15
3.3 Available models
Available models
Model
N. axes
Mec. size
Model
N. axes
Mec. size
5 A
1
1
8 A + 8 A
2
1
10 A
1
1
15 A + 5 A
2
1
15 A
1
1
2 A + 2 A + 2 A
3
1
30 A
1
2
5 A + 5 A + 5 A
3
1
2 A + 2 A
2
1
8 A + 5 A + 5 A
3
1
5 A + 5 A
2
1

Table of Contents