error code
Alarm Remedies
initialization error
Check the speed FBK settings.
Check the speed FBK connection.
Motor shaft in movement during the start-up.
The encoder is not phased. See the procedure.
Overloads digital outputs
Check the load of the digital outputs
Check the field-bus connection
“x” is a
Internal damage, to send to repair.
“The display
shows
decimal
points on all
characters
”
The drive goes in I
2
T mode due to an overload
(the current required is more than the current that
can be supplied).
Check :
The wiring between drive and motor (there
should be no inverted phases). Take special care
with motors where the connector is replaced by a
terminal block : it’s easy to make a mistake.
Adhere strictly to the wiring diagrams.
(*) reset only after default values have been loaded and saved.
(**) can be only reset at the next power on.
18.1 SUB Alarms table:
SUB Alarms Remedies
0
Insert the terminal plug-in
Power supply not 3-phases
3
17
Internal damage, to send to repair.
Number of axes configuration
Internal damage, to send to repair.
Internal damage, to send to repair.
4
ADC on FPGA error
Switch off the drive. Wait one minute
before of restart the drive.
Internal damage, to send to repair.
Internal damage, to send to repair.
Internal damage, to send to repair.
NIOS SDRAM checksum error
Internal damage, to send to repair.
Internal damage, to send to repair.
Internal damage, to send to repair.
Internal damage, to send to repair.
Internal damage, to send to repair.