SUB Alarms Remedies
Pr23
Pr24
Check the serial connection.
ExpBoard EEprom program error
24
Power supply not 3-phases
bit 1
Check the set up of the parameter Pr206
(by the first axis connected to the PSU).
bit 3
Check the environment temperature.
Check the cooling fans and for any
restrictions to air flow.
bit 4
Over load braking resistor
Check the cycle and if it’s necessary use
an external braking resistor.
bit 5
Check the connection of the temperature
switch (X40).
Short circuit on Braking control circuit.
bit 6
The current required is more than the
current that can be supplied
bit 7
Check for any mechanical blockage and
make sure the motor is the appropriate
size for its current use. Check the motor
connections and any phase-phase or
phase-ground short-circuits. Check the
length and type of the motor cable in
use. Make sure a mains filter isn’t
bit 14
Check the configuration (Pr206 of the
first axis connected to the PSU) of the
mains supply because it’s not correct.
Check the serial connection.