Parker Hannifin Manufacturing Srl user’s manual TPDM
Hold M pressed for 2 sec. while the name of a parameter (PRxx) is displayed to make the keypad
control switch to a different axis; a led will denote the active axis (A, B or C).
The following messages may be displayed on the screen, in addition to the value of the parameters
and the instructions of the pico-PLC:
Pr. Xx Indicates the parameter xx whose value can be displayed by pressing the [M] key.
Pb. Xx Indicates the parameter at bit xx.
bxx.yy Indicates the bit yy of parameter xx. By pressing the [M] key, the status of the bit is
displayed.
In. xx Indicates instruction xx of the PLC program.
donE Is displayed for about 1 second whenever a command is sent.
rESet Is displayed for about 1 second whenever an alarm reset command is sent (b99.10).
triP.x Indicates that the converter has malfunctioned.
If you cannot modify the read-write parameters using the keypad, be sure that b99.7 is 0; is it
was 0, probably the same parameters were modified by the pico-PLC program.
Pr...