Parker Hannifin Manufacturing Srl user’s manual TPDM
Par. Description Def.
(1) pre alarm PSU rectifier load.
(1) pre alarm PSU temperature.
(1) disable RS485 auto addressing.
(1) disable CAN auto addressing.
(1) pre alarm module-temperature.
(1) pre alarm board-temperature.
Pico-PLC: (0) single axis; (1) all pico-PLC in one, pico-PLC
common [only multi axes].
Parameters monitor: Pr160 = pointer, Pr162 = value, Pr163 =
value
Motor parameters calculation command. By this command, after
changed the motor parameters,
(1) EtherCAT parameters on Pr80…
Set encoder pulses as exponent on base 2. Decides the value of
Pr44
Multiturn feedback read. (1) Recognize a multiturn encoder.
IEC 61131 automatic memory extension. (1) the pico-PLC is
disabled (b99.13=0), the all instructions of the pico-PLC (512 byte)
are used as automatic variables for the IEC 61131 programming
Caught motor FBK: (0) = IN1; (1) = FBK C.
b231.7
Select supply voltage of feedback. (see the par. Select supply
voltage).
Attention: this function is managed only by A axis for all axes.
(1) encoder CAN via EtherCAT.
b231.11
PWM motor control switching frequency. There are three
possibility (see the appendix “switching frequency”).
Attention: the configuration is realized only on A axis
(1) enable profiles on TAB0. Enable profile on Tab0.
PTC motor pre-alarm (1). This pre-alarm allows to stop the
machine before (around 125°C – 257°F) reaching the alarm limit
Enable scope via COM. (1) Start. (0) Stop
Enable IEC 61131. (1) Start. (0) Stop