Master axis phase. If b150.8 = 1 at the first positive
front of digital input 0 or of the zero encoder input
(see the block diagram), the position of the master
Master axis phase captured. At each positive front
of digital input 0 or of the zero encoder input (see the
block diagram), the position of the master axis is
copied into in Pr124:125.
Master axis phase for engaging. If b150.12 = 1,
when the position of the master Pr112:113 exceeds
Pr126:127, Pr102 is brought to position 2 and
b150.12 returns to 0 to indicate that engaging has
Master axis phase for release. If b150.13=1, when
the position of the master Pr112:113 exceeds
Pr128:129, Pr102 is brought to position 1 and
b150.13 returns to 0 to indicate that the positioner
has been enabled and will control the release phase.
Engage cam with ramp. This is the position on
which the engage ramp related to the master starts.
Slave cam position. Read only parameter, depends
of Pr102, that shows the position at the output of the
Engage cam ramp. This is the step value performed
by the slave during the engage ramp; the value must
be less then an half of the slave axis module.
Multiplicative factor of reference ENCODER
CAN.
Divisor factor of reference ENCODER CAN.
ENCODER CAN input counter.
ENCODER CAN pointer (b70.10).
Master phase for engaging of Tab.0 (b180.0).
Master phase for engaging of Tab.1 (b180.1).
Master phase for engaging of Tab.2(b180.2).
Master phase for engaging of Tab.3 (b180.3).
Engage point inside to the master module of the
CAM.
Space in count of master module where the CAM
is executed.
Change of the value slave axis module in phase.
Variation of slave module, and with b181.12 slave