EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
51
Settings Menu: Man Heat (Off/On)
Bydefaultmanualheat(ManHeat)issetto“On,whichallowsyourspatobegintoheatwheneveritis
manuallyswitchedon,(bypressingtheValves (V)buttonandFilter Pump (F)buttonontheoutdoorcontrol
panelortheSpabuttonontheIndoorControlPanel),eveniftheHeatmenusettingissetto“OFF”(seepage
30).YourspawillalsobegintoheatwhenswitchedonbytheiS4Spa-Sideremote.Thisfeatureallowsyouto
programyourspatolterdailywiththeheatersettooff,andthenbereadytoheatwhenevertheSpabuttonis
pressedmanually.
Man Heat
Toenableordisablespamanualheatwhenswitchedonmanually:
MENUsSETTINGsMAN HEAT (ON/OFF)
Right button: SelectOfftodisableorOntoautomaticallybeginspaheating
wheneverthespaisswitchedonmanually.
PresstheMenubuttontosavethesettingsandtoreturntothemainscreen.
Settings Menu: Calibration
TheEasyTouchPL4/PSL4ControlSystemincludestwotemperaturesensors(10k)forwaterandambient
airtemperature.Youcanalsoaddanadditionalsensorforcontrollingsolarheatingsystems.Generally,these
sensorsareaccurateandyoudonothavetocalibratethem.However,longplumbingrunsandwaterfeatures
cancausetemperaturesatabodyofwatertobedifferentfromthetemperaturesensorreading.Youcan
manuallyrecalibratethesensorstoadjustforthis.Youonlyneedtocalibrateonebodyofwater,sincethe
temperaturesensoriscommontoboththepoolandspa.Thesystemmustbein“Service”modetocalibrate
sensors.
Calibration
Beforeyoustart,youneedanaccurateallweatherthermometer.Ifyouarecalibratingtheairsensor,waituntil
thesensorisnotindirectsunlight.Fortheairtemperaturesensor,makesurethatthesensorislocatedinthe
shadeforaccuratereadings.
Tocalibratethewater,airandsolartemperaturesensors:
MENUsSETTINGsCALIBRATIONwCALIBRATION
1. PresstheModebuttononthecontrolpaneltoplacethesystemin“Service”manualmode.
2. PresstheFilter Pump (F) buttontoswitchonthepool/spalterpump.
3. Placethethermometerinthespaorpoolwater.Takeanaccuratetemperaturereading.When
calibratingtheairsensor,placethethermometernexttotheairsensor.Theairsensorisnormally
locatednearorundertheEasyTouchPL4/PSL4ControlSystemPowerCenterenclosure,notinside
theenclosure.Takeanaccuratetemperaturereadingintheshade.
4. UsetheUporDown buttonstoraiseorlowerthewatertemperaturetomatchthecorresponding
thermometertemperaturereading.
5. Aftercalibratingthewatersensor,usetheRightbuttontomovetothe“AIR”settingandrepeat
step4andrepeattheprocedureforthesolarsensor.Ensurethatthesolarsensorisinthesunfor
accuratereadings.
6. Aftercalibratingallthesensors,pressthe Menubuttontosavethesettingsandtoreturntothe
Settingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagainto
returntothemainscreen.
QuickTouch
Man Heat [On]
Calibration
Calibration
Water: 70°F
Air: 80°F