EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
Settings Menu: IntelliChlor
WhiletheEasyTouch
®
PL4/PSL4ControlSystemisinnormaloperatingmode(“Pool,“Spa”modeor“SpaFill
(Spillway),itwillcontroltheIntelliChlor
®
SaltChlorineGenerator(SCG)chlorineoutputlevel.Theamountof
chlorineintroducedintothepoolisdeterminedbytheamountofsaltinthewater,watertemperature,andthe
amountoftimethepoolpumpisrunningin“Pool”mode.Note:Whilein“FreezeProtection”mode(seepage
44),theIntelliChlor(SC)willnotoperateorproducechlorineduringthetimethatthelterpumpisoperating.
Formoreinformation,refertotheIntelliChlorSaltChlorineGeneratorUser’sGuide(P/N520589).
IntelliChlor
TosetuptheIntelliChlor
®
SCG:
MENUsSETTINGSsINTELLICHLOR
Right button: Enable/DisabletheIntelliChlor.SCG(ToselectSuperChlor,runhours,
presstheUp/Downbutton-2/2).
Up/Down buttons: SelectYesorNotoenableordisabletheIntelliChlor(SC).
Right button: POOLMode“50%”setting.
Up/Down buttons: Setthechlorinationoutputlevelforthepoolwaterfrom0to
100%.EasyTouchPL4/PSL4ControlSystemwilldeterminethechlorinatoroutput
levelwhenthesystemisoperatingin“Spa”or“Pool”mode.Theamountofchlorine
introducedintothepool/sapisdeterminedbytheamountofsaltinthewater,water
temperature,andtheamountoftimethepool/spaoperatesinthesemodesmode.
Right button: SPAMode“0%”setting.
Up/Down buttons: Setthechlorinationoutputlevelforthespawaterfrom0to20%.
Right button: Movetothenextsetofsettings(2/2).
Up/Down buttons: Select2/2.
Right button: MovetheSuperChlorinationsettings.
Up/Down buttons: SetSuperChlorinationOnorOff.SeenotebelowaboutSuper
Chlorination.
Right button: Moveto“RunHours”setting.
Up/Down buttons: SetthenumberofhourstorunSuperChlorination.24hoursis
thedefaultsetting.Runhourscanbesetfrom0to72hours.
PresstheMenu buttontosavethesettingsandtoreturntotheSettingsmenu
options.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagainto
returntothemainscreen.
Note: For IntelliChlor (SC) status messages, see “Diagnostics: Chlorinator” page 58.
About Super Chlorination: TheSuperChlorinationfeatureisusedtointroducelargeamountsofchlorine
intothepoolwateriftherehasbeenheavyrainfall,manybathersinthepool,cloudywaterconditions,etc.
WhenSuperChlorinationisenabled,thesystemwillswitchonthelterpump,setthepool/spavalvestothe
correctposition,andsettheIntelliChlor(SC)tomaximumoutput.Thisprocesscontinuesfor24hours.Atthe
endoftheSuperChlorinationprocess,thepoolwillreturntonormaloperation.Itispossibletomanuallystop
theSuperChlorinationprocessandswitchoffthelterpumpusingtheFilter(F)buttononthemaincontrol
panelatthepoolequipmentpad.WhenthelterpumpisswitchedonagainusingtheFilter(F)button,the
SuperChlorineprocesswillresumeforthedurationoftimeleft.
IntelliChlor 1/2
Enable: No
Level: 50%
IntelliChlor 2/2
Super Chlr: Off
Run Hours: 24

Table of Contents

Other manuals for Pentair EASYTOUCH PL4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair EASYTOUCH PL4 and is the answer not in the manual?

Pentair EASYTOUCH PL4 Specifications

General IconGeneral
BrandPentair
ModelEASYTOUCH PL4
CategoryControl Systems
LanguageEnglish

Related product manuals