Status Message Possible Cause Solution
OK-NOERRORS
IntelliChlor(SC)normal
operatingmode.
N/A
SUPERCHLORINATE
IntelliChlor(SC)isin
“SuperChlorination”
modefor24hours.
IntelliChlor(SC)isin“SuperChlorinationmode
(seepage38ordetails)
COMLINKERROR
IntelliChlorSC
communicationerror
withEasyTouchPL4/
PSL4ControlSystem
circuitboard.
CheckcablefromIntelliChlorSCtoEasyTouchPL4/
PSL4ControlSystemcircuitboard.
CHECKFLOW/PCB
CheckIntelliChlor(SC)
electrolyticcell.
RefertoIntelliChlor(SC)User’sGuidetroubleshooting
information.
LOWSALT Addsalttopoolwater.
Thewatersaltlevelisbetween2500ppmand2900
ppm.TheIntelliChlor(SC)willcontinuetoproduce
chlorineatareducedlevel.SeeIntelliChlorSCGUser’s
Guidefordetails.
VERYLOWSALT Notenoughsaltinpool.
Thewatersaltlevelhasfallenbelow2500partsper
million(ppm).IntelliChlor(SC)willnotproducechlorine
untiladditionalsaltisaddedmanually.SeeIntelliChlor
(SC)User’sGuidefordetails.
HIGHCURRENT
CheckIntelliChlor(SC)
electrolyticcell.
CheckIntelliChlorelectrolyticcellcontroller.Referto
IntelliChlor(SC)User’sGuidetroubleshooting
information.
CLEANCELL!!
Cellhascalciumbuild
upandrequires
cleaning.
Cellhascalciumbuildupandrequirescleaning.Refer
toIntelliChlor(SC)User’sGuideforcleaning
instructions.
LOWVOLTAGE
CheckIntelliChlor(SC)
electrolyticcell.
RefertoIntelliChlor(SC)User’sGuidetroubleshooting
information.
Maximum Programs Exceeded
The“MaximumProgramsExceeded”messagedisplaysinthe“Schedules”menuifyoutrytocreateanew
programafterexceedingthefourprogramlimit.Tocreateanewprogramyoumustrstdeleteanexisting
program.Forinformationaboutdeletingaprogram,referto“ScheduleMenu”onpage32.
IntelliChlor Salt Chlorine Generator (SCG) Error Messages
TheIntelliChlorSaltChlorineGeneratorstatusanderrormessagesaredisplayedinthe“IntelliChlor”menu
(seepage38).UsethefollowinginformationtoresolvetheIntelliChlorSaltChlorineGeneratorproblems.To
accessthe“IntelliChlor”menu,pressMenu > Diagnostics > Chlorinator.

Table of Contents

Other manuals for Pentair EASYTOUCH PL4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair EASYTOUCH PL4 and is the answer not in the manual?

Pentair EASYTOUCH PL4 Specifications

General IconGeneral
BrandPentair
ModelEASYTOUCH PL4
CategoryControl Systems
LanguageEnglish

Related product manuals