EasyManua.ls Logo

Perfect Point E-Drill - Universal Flush Head Locator (FHL)

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15192 Triton Lane
Huntington Beach, CA 92649
Office Tel: 714-892-3400
Hotline Tel: 714-891-6533
www.ppedm.com
User Guide
Document No.
Revision:
107
Date:
10/18/2018
This document is the property of PPedm Corp. and contains proprietary and/or patented information and may not be reproduced in
part or in whole without the express written permission of the company. Perfect Point logo, Perfect Point
TM
and E-Drill
®
are
trademarks of PPedm, Corp. US and worldwide patents pending.
Page 35 of 76
2.5.1 Universal Flush Head Locator (FHL):
The Universal Flush Head Locator (p/n
EDF0120) is intended for skin removal
where the skin is to be replaced, or
where high precision is not necessary
(such as where larger fasteners are
going to be installed as replacements).
For flush head fasteners the procedure
is the same as for button-head fasteners
except that a different E-Drill Adapter is
used in conjunction with a Flush Head
Locator (FHL). The photograph below
depicts the FHL and proper alignment.
To configure the E-Drill for removal of flush fasteners; select the correct fastener type
on the Touch-Screen Display. Identify from the screen which Electrode and Electrode
Guide are required, and install the electrode, adapter and guide on the hand tool (see
Appendix 2 for details). Clean off any paint or other coatings so that the E-Drill will
make good electrical contact, and you can clearly see the outline of the fastener head.
A)
FHL’s are provided with a range of sizes of sighting apertures suitable for
different fastener head sizes. Select a suitable size FHL aperture.
B)
Place the FHL over the fastener head, using the sighting aperture to ensure
the FHL is concentric.
Flush Head Locator Alignment

Table of Contents

Other manuals for Perfect Point E-Drill