OPERATING ENVIRONMENT:
The Perfect Point E-Drill system should be protected from freezing cold conditions that can crack or
burst de-ionized water connections and plumbing. If the system is subjected to freezing temperatures,
it should be thoroughly inspected by a trained technician for damage or leaks prior to use. If the system
is to be stored or transported in low temperature conditions, then it should be fully drained first (see
System Maintenance - section 4.1).
The Perfect Point E-Drill system should not be operated in the rain or snow. If aircraft repairs
necessitate outdoor operation in severe weather conditions, it is recommended the Mobile Service
Unit be positioned under a protective awning or positioned in a protected area under or in the airframe.
Cable connections should not be left in pooled water and should be kept elevated.
LETHAL VOLTAGES PRESENT
All power supplies contain hazardous voltage and energy. The E-Drill system should only be operated
by qualified personnel who have read this operator’s manual and are familiar with the operation,
hazards, and application of the E-Drill system. Proper care and judgment must always be observed.
1.
Never attempt to operate the E-Drill system in any manner not described in this manual.
2.
Ensure all covers are in place and securely fastened and the required grounding is supplied
before connecting the input AC power.
3.
Proper grounding from the input AC power is required to reduce the risk of electric shock,
and to comply with safety agency and code requirements.
4.
Use extreme caution when connecting the input AC power and only apply the input voltage
specified on the rating label.
5.
Ensure power switch is in the OFF position prior to accomplishing any service procedures.
6.
Never remove DANGER or WARNING labels from the power supply and replace lost or
damaged labels immediately.
7.
The Mobile Service Unit, Compact E-Drill, and Umbilical Cables, should only be serviced by
Perfect Point Corp. factory qualified personnel.
8.
Do not operate the system in the rain, snow, or freezing weather without providing proper
environmental protection.