C)
When using a CG system, using a small drill bit, clean out the hex hole if
one exists. There is no need to remove metal simply remove any loose
debris or coatings inside the hole such that good electrical conductivity will
occur.
D)
In order to ensure longevity of the O-ring inside the collar adapter it is good
practice to grease the inside of the collar adapter or the outside of the collar.
Push the E-Drill Adapter lightly over the collar, completely enclosing it. Allow
the Adapter to determine the concentricity and alignment of the hand-tool.
Press down to make a seal and squeeze the trigger.