PG DRIVES TECHNOLOGY I-DRIVE TECHNICAL MANUAL – TRUCHARGE MODULE
3 Mounting
3.1 Handling
The TruCharge Module contains electronic components that may be sensitive to static electricity. Always store the modules in the
original packaging until they are ready to be used. When the modules are removed from the packaging, ensure correct anti-
static precautions are observed.
3.2 Surface Variant
3.2.1 Fixing
The machine’s control panel should be fitted with holes as suggested in the diagram below.
3.2.2 Sealing
The supplied single-sided adhesive gasket (adhesive uppermost) should be used to create a seal between the TruCharge
Module and the machine’s control panel. See the following illustration.
When correctly fitted, this arrangement will give the TruCharge Module an IPX5 ingress protection rating.
SK76977-07 9